Customization: | Available |
---|---|
Type: | Storage Battery Tester |
Test Region: | Charge and Discharge |
Still deciding? Get samples of US$ 5200/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Battery Type | Specification | Capacity |
Lead-acid batteries | 6V/12V/16V/18V | <200Ah |
1. Charge | 2. Discharge (Capacity Test) |
3. Auto-cycle Charge and Discharge |
Model No.: | DK-G48/SF200 |
Channel Number: | 48 |
Discharge current accuracy: | +/-0.03A |
Discharge voltage accuracy: | +/-0.03A |
Charge current accuracy: | +/-0.1A |
Charge voltage accuracy | +/-0.05V |
The minimum charge voltage | 7.0 V |
The maximum charge voltage | 23V |
The transfer condition of charging and floating charge |
After reaching the high constant voltage and charge for 3.5h, the system automatically transfer to the floating charging |
Discharge current | 0.5-20A constant current adjustable |
Charge current | 0.5-10A constant current adjustable |
Loop number: | 1-50 times |
Discharge terminal voltage: | 2.0V-20V adjustable |
Charging constant voltage: | 7.0V-23V adjustable |
Model | Product Size | G.W. |
DK-G48/SF200 | 2160*400*170 mm | 185 KG |